Fire Detection

A fire detection system is number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present. These alarms may be activated from smoke detectors, and heat detectors. Alarms can be either motorized bells or wall mountable sounders or horns.

They can also be speaker strobes which sound an alarm, followed by a voice evacuation message which warn people inside the building not to use the elevators. They may also be activated via Manual fire alarm activation devices such as manual call points or pull stations.

Sigma Power Tech is a company committed to continuous improvement to ensure we always deliver the highest standards of service. We have been installing Fire equipment for 4 years. Our team has the Experience in both the Domestic and Commercial Markets.

We supply and install most makes of fire alarm systems (Edward, Morley, Shrack Seconet, Secutron (By Mircom), Schneider Electric, Bosch Systems), a complete range of advanced UL / ULC / FM listed conventional and addressable systems, detectors, signaling devices, accessories and service tools for any new or retrofit application.


Addressable/Conventional Fire Detection System

Features:

  • Intelligent, microprocessor-based devices, including multi-sensor detectors that provide warning of smoke and fire conditions.
  • Advanced photoelectric sensing technology.
  • Fire drill.
  • Pre alarm.
  • Priority to Alarm.
  • Supervisory.
  • System Reset.
  • Acknowledge.
  • Mains healthy indicator.
  • Continuous alarm signal.
  • Built-in battery


Aspiration Detection-VESDA (Very Early Smoke Detection Apparatus)

Aspiration Detection (VESDA) Features:

  • High intensity status LEDs for greater visibility.
  • Robust absolute smoke detection.
  • Patented Intelligent Filter.
  • Lint Trap to capture fibrous particulates.
  • Sub-sampling Probe (inertial separator).
  • Secondary Filter.
  • Clean air barrier for optics protection.
  • Referencing.
  • Auto Learn™ Smoke and Flow.
  • Clean Air Zero™.
  • Air-path monitoring.
  • Multi relays (Fire, Fault and configurable).
  • Relays configurable as latching or non-latching.
  • Expandable GPI and relays.
  • Ultrasonic flow sensing.
  • IP66 Enclosure.
  • Easy mounting through steel support bracket.
  • Modular field replaceable parts for ease of servicing.
  • Modbus/BACnet.
  • Local USB configuration port.
  • Easy cable termination access.
  • Imperial and metric pipe ports.
  • Rubberized finish to external housing.

We are a professional firm providing Fire sprinkler systems, High Pressure Water Mist System, & Gas Suppression System. We encourage our team member’s growth through personal and professional development to enhance sustained growth of our company. We engage in active partnerships with our clients to provide design-focused solutions with an unyielding approach toward results.

With a collective experience of more than 3 years by now, our main expertise comprises of consultancy, design, execution and maintenance of Fire Fighting Systems. With an exposure to working with renowned Indian Consultants & Clients, we have developed the capabilities to meet stringent design standards laid down by NFPA, NBC and other relevant authorities.

A team of more than 15 skilled professionals strongly supports our customers in turnkey project solutions for firefighting systems. Need based solutions in almost all type of industries is what we excel in, along with the AMC of the system.


Fire Sprinkler Systems:

The automatic sprinkler and fire alarm system shall be designed to extinguish a fire in its early stages using water and simultaneously sounding an alarm to summon help. Pipe work fitted with sprinklers at regular intervals is connected to a reliable water supply.

Each sprinkler is an automatic heat sensitive valve, which opens independently in the event of fire to discharge water on to the seat of the outbreak. Only the sprinkler or sprinklers affected by fire operate, and the opening of any one sprinkler immediately sounds an alarm.

Generally, the sprinkler system shall be provided in basement floor, Air Conditional Areas. The sprinkler heads are to be fixed into GI pipes of sizes 25mm to 100mm to suit the hydraulics of the system and confirming to the guidelines. The entire piping system shall be capable of withstanding test pressure of 15Kg/sq. cm.


High Pressure Water Mist System

High-pressure water mist system is an innovative and unique system of fire extinguishing, widely used at protection of many different objects.

Water is forced through micro nozzles at very high pressure to create a water mist with the most effective firefighting drop size distribution. As the consequence of constant cooling of the extinguished area, re-ignition is avoided.


Water Mist Extinguishing Systems Provice:

  • Rapid reaction to fire.

  • The most effective cooling of extinguished areas.

  • Safety of people, environment and property.

  • Avoidance of the re-ignition.

  • Conduction of 90% less water, used by classic sprinkler systems.

  • Minimalizing damages, caused during fire extinguishing.

  • Small size and low system weight.

  • Low costs of re-filling of the system.


Infra-Sensing:

  • A regular temperature sensor provides you with the temperature of the air surrounding the sensor. The thermal camera sensors provide you with the temperature of the objects & equipment it sees.

  • The world's first SNMP & Modbus (TCP & RTU) thermal camera sensor that tells you the temperature of what it sees. From 192 up to 19200 temperature measurement points in one image, analysed every 2 seconds. Up to 5 thermal camera sensors supported per Sensor Gateway (BASE-WIRED) with the optional.